TRD-Z DC Fuse(PV Special)
Type and Meaning
Note: rated current:1、2、3、4、5、6、8、10、12、15、20、25、30A
Application Environment
Ambient temperature:-40℃~+90℃
◎ Elevation :≤3000m
◎ Relative humidity: the relative humidity of the air must not be above 50% at the max temperature of +40℃, but it may be higher at a lower temperature. The max average relative humidity must not be above 90% in the most humidity month in which the minimum average temperature is not above 25℃.Dew on the protectors due to temperature alteration should be removed.
◎ There must be not any explosive medium, and there must be not any gas which would corrode metal or any con-ducting dust which would destroy the insulation.
◎ Pollution level: level 3
Main Technical Parameters
TRD-Z | Technical parameters |
Rated current(A) | 1、2、3、4、5、6、8、10、12、15、20、25、30 |
Rated operating voltage (v) | DC1000 |
Rated insulation voltage(v) | DC1500 |
Rated short-circuit breaking capacity | 25kA |
Pole numbers | 1P |
Installation method | TH-35 Rail installation |
Time Current Characteristic
Outline and Mounting Dimensions
Type | Specifications | Dimensions | ||
TRD-Z | 10×38 | L(mm) | Hmax(mm) | Φ(mm) |
38±0.6 | 10.5 | 10.3±0.1 |